Water Treatment Systems for Asbestos Decontamination

Deconta water treatment systems for asbestos decontamination wastewater, filtered to 1 micron.

  • Filters to 1 micronCaptures asbestos fibres from wastewater
  • Heated pump systems2000W to 3000W, single or dual pump
  • EPA & WHS compliantSafe stormwater and sewer discharge
  • Australia-wide deliverySpecialist support

    Speak to our sales team

    Choosing the right water filtration or management system

    Contaminated water can be generated in many ways during asbestos and hazardous-material work, from personnel decontamination showers and equipment wash-down through to ponded water, sumps and other contaminated water collected inside a work area.

    Deconta offers two different types of equipment to manage this:
    Wastewater filtration systems such as the AS range are designed to pump contaminated water through staged filtration down to 1 micron. They can operate as standalone filtration units and are not limited to use with decontamination showers.
    Water management systems such as the SW range combine wastewater filtration with the supply of heated water for personnel decontamination, providing a more complete solution for wet decon facilities.
    The right system depends on the volume of water, contamination load, required flow rate and whether heated fresh water is also required.

    AS200
    The AS200 is a compact standalone wastewater filtration system designed to pump and filter contaminated water through a two-stage filtration process.
    It can be used with a decontamination shower, but it is equally suitable for other applications where contaminated water needs to be removed and filtered — for example ponded water or a small contaminated sump within an asbestos work area.
    Best suited for:
    Smaller-volume contaminated water filtration where a simple, portable system is required.

    AS300
    The AS300 is a higher-capacity standalone wastewater filtration system with three-stage filtration and pressure monitoring.
    It provides greater filtration capacity and easier monitoring of filter loading, making it suitable where larger volumes of contaminated water need to be processed.
    Best suited for:
    Higher water volumes, ongoing filtration work or applications requiring additional filtration stages and monitoring.
    AS300CG
    The AS300CG builds on the AS300 with an additional coarse filtration stage ahead of the main filters.
    This helps remove larger material earlier in the process, reducing premature loading of the finer downstream filters.
    Best suited for:
    Contaminated water with heavier solids or debris where additional pre-filtration is beneficial.
    SW50L
    The SW50L is a complete water management system for wet personnel decontamination.
    It combines heated fresh-water supply with wastewater filtration and incorporates one fresh-water pump and one wastewater pump in a compact integrated unit.
    Best suited for:
    Standard wet decontamination setups requiring both heated shower water and wastewater filtration from one system.

    SW120L
    The SW120L is the premium, high-capacity water management system for demanding decontamination setups.
    It features a 120 L heated-water capacity and dual wastewater pumps, allowing separate shower chambers to be drained independently.
    This solves a common problem with single-pump systems serving multiple chambers: if one chamber is empty, the system can draw air from that chamber instead of maintaining effective suction where wastewater is actually present.
    By giving each wastewater pickup its own pump, the SW120L eliminates that issue and provides more reliable drainage, fewer suction problems and less operator intervention.
    Best suited for:
    Higher-throughput decontamination systems, multiple shower chambers and contractors wanting the most complete, low-headache water management solution.

    Requirement Recommended system Why
    Small-volume contaminated water filtration AS200 Compact standalone two-stage filtration
    Higher-volume contaminated water filtration AS300 Three-stage filtration with pressure monitoring
    Contaminated water with heavier solids/debris AS300CG Additional coarse filtration protects downstream filters
    Integrated heated water + wastewater management for decon SW50L One fresh-water pump and one wastewater pump
    Higher-throughput or multiple shower chambers SW120L Large heated-water capacity and dual wastewater pumps for independent drainage

    Standards and compliance

    • Wastewater from decontamination showers and equipment wash-down must be filtered before disposal, not released untreated to stormwater or sewer, consistent with Safe Work Australia guidance, local WorkSafe regulators and EPA trade waste
      requirements.
    • Filtration to 1 micron or finer is the practical benchmark for capturing asbestos fibres from wastewater.
    • Match pump and heating capacity to the number of showers running at once; an undersized system is a common cause of non-compliant discharge on busy sites.
    • Keep filtration and disposal records alongside your other decontamination
      documentation for site audits.

    Frequently asked questions

    Why do I need a water treatment system, not just a decontamination shower?

    A decontamination shower removes contamination from workers and equipment, but the wastewater produced can itself be contaminated. A suitable water treatment system is used to collect and filter that wastewater before it is discharged or disposed of in accordance with site and local authority requirements. Filtered water should not be assumed to be automatically suitable for stormwater or sewer discharge the applicable disposal requirements still need to be followed.

    What does 'filters to 1 micron' actually mean?

    It means the system uses staged filtration down to a 1-micron final filter, removing very fine suspended particles from contaminated water rather than just visible sediment. This helps capture asbestos-containing material and fibres carried in the wastewater before further disposal or discharge in accordance with site requirements.

    Who needs one of these systems?

    Any contractor who needs to collect and filter contaminated water during asbestos, mould or hazardous-material work. That can include wastewater from decontamination showers, equipment wash-down, ponded water, sumps or other contaminated water within the work area. The right system depends on the water volume, contamination load and required flow rate.

    What's the difference between the AS300 and AS300CG?

    The AS300CG adds an additional coarse filtration stage ahead of the main filters, giving it a 4-stage filtration setup better suited to wastewater with heavier solids or debris. It also includes manometer monitoring to help track filter loading. An optional proximity/level sensor can also be added to automatically start and stop the pump as the water level changes, reducing the need for manual operation. The standard AS300 remains a strong choice for general contaminated-water filtration where the extra coarse stage and automatic pump control are not required.

    Do I need a dual-pump system?

    Not always. A single wastewater pump is suitable for many standard setups. Dual wastewater pumps are most useful where multiple shower chambers or wastewater pickup points need to be managed independently. The advantage is that one empty chamber cannot cause the system to suck air and reduce suction from the chamber that still contains water. This gives more reliable drainage, less manual intervention and fewer operational headaches. For higher-throughput or multi-chamber decontamination setups, the SW120L is the preferred option because of its dual wastewater pump design.

    How often do filters need replacing?

    This depends on water volume and contamination load. Follow the manufacturer's service schedule and watch for reduced flow as an early sign filters need changing.

    Are spare parts and filters available locally?

    Yes, contact our team for current stock on filters and spares for your model.

    How long do these systems typically last?

    There is no fixed service life. These are German-made industrial systems built for repeated professional use, and with proper cleaning and maintenance they can remain in service for many years. Filters are consumable items, while pumps, heaters, hoses, seals and other components can be serviced or replaced as required. If something does fail, DeconSafe provides local support, repairs and access to genuine spare parts, so you are not left stranded with an unsupported machine.

    Can I hire a water treatment system?

    Speak to our team about hire options if you need a system for a single job rather than an ongoing purchase.

    How quickly can a system be delivered?

    Delivery times vary by model and stock on hand. Contact our team with your required date and we'll confirm what's achievable.